CARE AND CLEANING
To clean the outside stainless steel surface,
wipe with a damp cloth or spray with
window cleaner and dry with a clean towel
or kitchen paper.
CLEANING
Unplug cord from power point then remove
percolator from base. ALLOW the percolator
to cool before cleaning.
Wash and rinse the inside of the percolator,
water tube, lid , filter basket and basket lid
with hot soapy water, then rinse with cold
water after each use.
Removal of mineral deposits
Continual use and the use of hard water can
cause the build up of mineral deposits in the
percolator body and water tube. If these
deposits are not removed, the brew time
can become excessive. The build up of oils
and stains can also occur from inside the
percolator.
To remove coffee stains from inside
percolator dissolve 1 tablespoon of
Bicarbonate of Soda with 1 cup of warm
water and pour into base of percolator add
sufficient water to cover affected areas.
Stand for several hours or overnight. Rinse
thoroughly.
´
CAFE CORDFREE
COFFEE MAKER
To remove any deposits as well as oils and
stains the following steps can be taken.
Periodically remove oils and stains from
inside the coffee maker with a kettle
descaler product available from electrical
departments in major department stores.
Do not immerse the coffee
☛
percolator or cord and
NOTE!
base in water or other
liquid.
Breville is a registered trademark of Breville Holdings Pty. Limited
ABN 98 000 092 928
Breville Customer Care Centre
Australian Customers
Breville Customer Care Centre
Locked Bag 2000
Botany NSW 2019
Australia
✉
Customer Service
Ph: 1300 139 798
¤
Fax (02) 9384 9601
Email Customer Service
New Zealand Customers
Breville Customer Service Centre
Private Bag 94411
Greenmount
✉
Auckland, New Zealand
Customer Service Ph: 09 271 3980
Fax 0800 288 513
PRINTED ON
RECYCLED PAPER
¤
Email Customer Service
Model CMP12
Issue 1/97
INSTRUCTIONS FOR USE
CMP12
© Copyright. Breville Holdings Pty. Limited 2004
Due to continual improvements in design or otherwise, the product you
purchase may differ slightly from the one illustrated in this booklet.
OPERATING YOUR BREVILLE CAFÉ CORD FREE
KNOW YOUR BREVILLE CAFÉ CORD FREE
water tube is not seated properly, the
percolator will not perk. Slip the basket
on the water tube.
BEFORE THE FIRST USE:
Before percolating coffee for the very first
time, clean the Café Cordfree as follows:
1. Stainless steel percolator body with 12
5. Multi directional 360 power base for
cup capacity
convenient cordfree operation.
6. Cord storage under base
7. Stainless steel filter basket
8. Stainless steel filter basket lid
9. Stainless steel water tube
2. Stainless steel percolator lid with clear
handle allows you to view the coffee
percolating process.
1. Remove any promotional labels and
packaging from the unit.
Failure to replace the
basket lid may result in the
coffee grounds overflowing
into the liquid.
☛
3. Easy to grip cool touch handle.
NOTE!
2. Wash the insides of the coffee percolator,
lid, water tube, basket and basket lid with
hot sudsy water.
4. ‘Coffee ready’ signal light comes on
automatically when coffee is ready to
drink. The coffee ready light will continue
to glow indicating the percolator is
keeping the coffee warm.
3. Rinse all parts thoroughly with clean cold
water.
Firmly replace percolator lid.
5. Place the power base on a level surface
and place percolator on base. Connect
power plug to a 240V power outlet and
switch power on.
DO NOT IMMERSE CAFÉ CORDFREE
PERCOLATOR OR CORDLESS BASE IN
WATER OR ANY OTHER LIQUID.
2.
PERCOLATING COFFEE
For perfect coffee every time, always fill your
percolator with fresh COLD water.
Never turn the power to
the percolator on without
water or liquid coffee in it.
Never operate percolator
when empty.
☛
3.
NOTE!
1. Remove filter basket, filter basket lid and
water tube from inside the percolator
body.
8.
7.
2. Fill the inside of the percolator body with
fresh cold water to the desired cup
measurement levels, marked between 6
and 12 cups inside the percolator body.
Make at least 4 cups or more at a time to
assure best flavour.
The ‘Coffee ready’
indicator light will not
illuminate UNTIL the coffee
percolating process is
finished.
☛
NOTE!
3. Add coffee (medium ground for
percolator) evenly inside the filter basket,
approximately 1 level tablespoon per cup,
depending on your taste. (see suggested
amounts below). When adding coffee to
basket , place finger over the stem to
prevent coffee from falling through. Cover
the basket with basket lid.
When the coffee has finished percolating the
‘coffee ready’ signal light will illuminate to
indicate the coffee is ready. The coffee will
then automatically keep the coffee warm
until the percolator is switched “off”.
1.
9.
Switch the percolator “off” at the power
point when the percolator is empty or when
oyof u no locnogfeferewant to keep the coffee
warm.
4.
Cups
4
of
brewTablespoons
4-5
6
5-6
NEVER leave the
percolator plugged into the
power point if it is empty of
liquid as permanent
☛
8
6-8
NOTE!
10
12
8-10
8-12
5.
damage may result.
4. Seat the water tube into the bottom of
the percolator (rounded bottom of tube
sits in bottom of the percolator). If the
6.
3
4
BREVILLE RECOMMENDS SAFETY FIRST
TO MAKE ADDITIONAL COFFEE
IMMEDIATELY.
• Switch the Café Cordfree off at the power
point.
TO REHEAT COFFEE.
• To reheat, remove the filter basket and
water tube from the percolator.
Congratulations on your purchase of your
new Breville Café Cordfree coffee maker.
We at Breville are very safety conscious.
We design and manufacture consumer
products with the safety of you, our valued
customer, foremost in mind.
Service Centre for examination, adjustment
or repair.
In the interests of safety, regular periodic
close checks should be carried out on the
supply cord to ensure no damage is evident.
Should there be any signs that the cord is
worn, cracked or damaged in the slightest
degree, the entire appliance should be
returned to your nearest authorised Breville
Service Centre for repair or replacement.
• Replace lid and place percolator on the
power base
• Taking care not to touch hot parts, wash
and rinse the inside of the percolator
body, filter basket and water tube, rinsing
with COLD water.
• Switch “on” at the power point.
In addition, we ask that you exercise a
degree of care when using an electrical
appliance and adhere to the following
instructions.
• Café Cordfree will heat and ready light will
illuminate when coffee has reached the
correct temperature. The time will vary
depending on the amount of coffee in the
percolator.
• Follow the steps under “Percolating
Coffee”.
READ THESE INSTRUCTIONS BEFORE
OPERATING AND SAVE FOR FUTURE
REFERENCE.
The appliance is not intended for use by
young children or infirm persons without
supervision.
• Do not reheat with less than 4 cups in
the coffee maker.
Do not touch hot surfaces. Use handles.
This appliance is intended for household use
only. Do not use this appliance for other
than its intended use. Do not use outdoors
Do not immerse power base, plug or
percolator body in water or any other liquid.
HINTS FOR BEST RESULTS
Always use the appliance on a dry level
surface.
Do not allow the cord to hang over
counters, benchtops or similar. Use the
cord shortener facility in the power base.
Ensure that the percolator jug, basket, water
tube and lid are all kept clean and free from
grease or sediment which can impair the
coffee flavour - clean them after each time
used.
for each cupful, but adjust according to
taste.
Warning – External
Surfaces may become hot
during operation and could
cause injury. Breville
recommends using
handles only, when unit
is heated.
Do not open lid while the percolator is in
use. Make certain the lid is firmly in place
before the percolator is switched on.
Always use fresh cold water for making the
coffee.
Coffee left on keep warm for longer than 1
hour will loose flavour and become bitter.
Never boil brewed coffee as it will become
bitter.
Do not place the percolator on an electric
hot plate, gas flame or in an electric oven.
Use only coffee recommended for use in
percolators. Medium coarse ground. Using
finely ground coffee such as that suitable for
a filter coffee maker can result in the ground
coffee falling through into the percolated
coffee.
If this appliance becomes damaged in any
way return to the nearest authorised Breville
To maintain coffee freshness, reseal opened
packets of coffee or place in airtight
container, then store in the refrigerator or
freezer.
It is recommended that you use 1 level
tablespoon of medium coarse ground coffee
5
2
|